ACDC-400 Digital AC/DC Clamp-on Multimeter
ACDC-400 Digital AC/DC Clamp-on Multimeter
A AC/DC, V AC/DC,...
- AC/DC Current up to 400A
- AC/DC Voltage up to 600V
EUR 187.99
excl. VAT
excl. VAT
Article code: 110-400
- Product info
- Related products
The ACDC-400 clamp meter is full featured with wide measurement capabilities. It measures both AC and DC Current to 400 amps, AC and DC Voltage to 600V, plus Resistance and Continuity. The ACDC-400 also offers software features of Min/Max and Relative measurements with a large digital and analog combined display and backlight.
- Display : 3-3/4 digits 4000 counts LCD display
- Update Rate : 2 per second nominal
- Polarity : Automatic
- Power Supply : 2 standard 1,5V AAA battery
- Battery Life : typical 25 hours
- APO Timing : idle for 30 minutes
- Low battery : indication on LCD; approx. 2,4V
- Environment : indoor operation, below 2000 m
- Temperature Operating : 5°C to 40°C (41°F to 104°F)
- Humidity Operating : < 80% RH
- Storage: -10°C to 60°C (14°F to 122°F), < 80% RH
- Jaw opening : 27 mm max
- Dimensions : 202 x 70 x 40 mm
- Weight : 254 gm
Features
- AC/DC Current up to 400A
- AC/DC Voltage up to 600V
- Resistance measurement
- Continuity test
- Data Hold
- MAX/MIN recording
- Relative measurement
- Backlight
- Analog bargraph
- Auto or Manual range selection
- Max Conductor 29,97 mm (1.18”)
- Includes carrying case
- CAT III 600V
EMC
This apparatus was designed in accordance with EMC standards in force and its compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).
Safety
Comply with : EN 61010
Insulation : Class 2, double reinforced insulation
Pollution : Level 2
For inside use, max height : 2000m
Over voltage : CAT III 600V (between ground & input terminal)
Certifications
Safety LVD : Meets EN60101-1:2001; EN61010-2-032(2002), Category II- 600 Volts ac & dc; pollution degree : 2; class 2
CE EMC : EN61326-1:2006
Standard Accessories
- Instrument
- Test leads (MTL-90B)
- Rubber test lead holster (MTL-CAP)
- User’s manual
- Carrying case (SV-U)
- Batteries
Electrical Specifications (23 °C ± 5 °C) < 75%RH
DC Voltage | Range | Accuracy | |
400.0 mV 4.000V, 40.00V, 400.0V | ± (0.8% rdg + 2 dgts) | ||
600V | ± (1.0% rdg + 2 dgts) | ||
Input impedance | 10 MΩ 30pf nominal ( 100 MΩ for 400.0mV range) | ||
Max input | 600 VDC | ||
AC Voltage (sinusoidal) | Range | Frequency | Accuracy |
400.0mV | 40Hz to 60Hz | ± (1.0% rdg + 50 dgts) | |
4.000V, 40.00V, 400.0V | 50Hz to 500Hz | ± (1.0% rdg + 3 dgts) | |
600V | 50Hz to 500Hz | ± (1.2% rdg + 3 dgts) | |
Input impedance | 10MΩ, 30pf nominal ( 100 MΩ for 400.0mV range) | ||
Max input | 600 VAC rms | ||
DC Current (Clamp-On) | Range | Accuracy | |
0.00A to 40.00A | ± (2.0% rdg + 10 dgts) | ||
40.0A to 400.0A | ± (2.0% rdg + 10 dgts) | ||
Max current | 400A rms continuous; 600 A rms ( 60 seconds) | ||
AC Current (Clamp-On) (sinusoidal) | Range | Frequency | Accuracy |
0.00A to 40.00A | 50Hz to 60Hz | ± (2.0% rdg + 10 dgts) | |
40.0A to 400.0A | 50Hz to 60Hz | ± (2.0% rdg + 10 dgts) | |
Max current | 400A rms continuous; 600 A rms ( 60 seconds) | ||
Resistance | Range | Accuracy | |
400.0 Ω | ± (1.0% rdg + 5 dgts) | ||
4.000kΩ, 40.00k Ω, 400.0k Ω, 4.000M Ω | ± (1.0% rdg + 3 dgts) | ||
40.00MΩ | ± (3.0% rdg + 3 dgts) | ||
Open Circuit Voltage | 0.45 Vdc typical; 1.5 Vdc typical for 400.0 Ω | ||
Continuity Tester | Open Circuit Voltage: 1.4Vdc typical Audible threshold: < 40 Ω |